![]() Refer to the calibration section for more information about how to calibrate the RadBeacon E4. For properly calibrated devices, set the transmit power to +4 dBm for a 30 meters estimated radius of coverage. Increasing the transmit power reduces the lifespan of the RadBeacon E4’s battery. The transmit power is proportional to the area coverage of the wireless signal. The “Transmit Power” value determines the strength of the wireless signal transmitted by the RadBeacon E4. Increasing the “Advertising Interval” value increases the lifespan of the RadBeacon E4’s battery. The recommended interval value for iBeacon advertisement is 100ms. The “Advertising interval” value is used for configuring the frequency rate at which the slot advertises data. The “Channels” option is used for switching advertisement on/off on the 3 individual Bluetooth™ Low Energy advertising channels. The “Enabled” switch is used for starting/stopping advertisement activity on the slot. Once the slot has been enabled, the list of slot configuration options will expand as shown in the figure below. To start configuring the slots, tap the “Enable” toggle switch to the ON position. The “Battery” field shows the current percentage of remaining battery in the device. The “MAC address” fields corresponds to the address of the beacon. The “Version” field indicates the firmware version of the beacon. The beacon information section displays status information about the connected device. If a name containing more than 32 characters is applied as part of the changes, it will be ignored. To edit the beacon name, start by tapping on the beacon name edit box under the “Beacon Name” label.The beacon name can be set to a maximum length of 32 characters. The Beacon Detail screen contains fields for configuring the beacon parameters, and fields that display beacon status information. ![]() Note: If the Beacon list remains empty after 15 seconds of scanning, we can assume there are no RadBeacon E devices in range. Next, you should see a progress icon with a message indicating that scanning has started, as shown below.Īfter a few seconds of scanning, the home screen should list the available in-range devices. The device scanning process is initiated by pulling down on the home screen of the RadBeacon E App. The RadBeacon E App allows users to configure their RadBeacon E4 device parameters. Only while in configuration-mode the beacon will broadcast connectable advertisements. The beacon will remain in configuration-mode for the next 10 minutes. The blue LED will blink twice to confirm beacon has entered configuration-mode. Configuration-mode is entered after pressing and releasing the button while not in configuration-mode. The button on the side of the beacon is used for enabling configuration-mode. ![]() Refer to the slot configuration section below for details on how to enable/disable a slot. The E4 can be switched off by disabling all the 5-slots on the beacon using the RadBeacon E app. The RadBeacon E4 allows for user configuration via the RadBeacon E App available for iOS and Android devices. The RadBeacon E4 is powered from 4 user-replaceable AA batteries. The RadBeacon E4 can be configured to advertise data in up to 5 individual slots. The RadBeacon E4 supports the 4 most popular beacon protocols iBeacon, AltBeacon, Eddystone UID, and Eddystone URL. This will restart the 30 minute configuration window and your beacon should show up in subsequent scans.The RadBeacon E4 is the next generation Radius Networks Bluetooth™ Smart proximity multi-beacon device. If you are unable to discover your beacon using the RadBeacon Config App, unplug the RadBeacon, wait 5 seconds, and plug it back in.This feature is a security precaution to limit the possibility of third party manipulation of your beacons once they have been installed and configured. After this 30 minutes period elapses, the beacon will no longer be connectable from other Bluetooth 4.0 devices without restarting that window. Beacons are only initially configurable for a period of 30 minutes after they are powered.It is highly recommended that you make a priority changing the PIN for your RadBeacon device. As with previous versions, the default PIN is all zeros, or '00000000'. With version 3.2.3 we are introduced stronger eight (8) digit PINs. For firmware versions prior to version 3.2.3, configuration of beacons requires a four (4) digit PIN. With the RadBeacon app you can scan for nearby configurable RadBeacon proximity beacons, display their operating settings and make modifications to those settings.Download the RadBeacon Config App for you device.In addition to full control over the beacon advertisement data configuration, the transmit power and advertising rate are adjustable to suit a wide variety of deployment scenarios. RadBeacon USB is over-the-air configurable using the RadBeacon App for iOS.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |